Page 32 - PowerPoint Presentation
P. 32

Let’s all
                              LIFTING WITH EXCAVATORS                                                             get home safely,
                                                                                                                  every day




      Consider if an excavator is appropriate for the lifting operation and have an approved
      lift plan in place.
      Excavators used for lifting must comply with the John F Hunt Ltd plant standards and be
      fitted with:


                                                    Compatible attachments
                                                    with safe working load (SWL)
                                                    indicated (and included in
                                                    weight of the lift).
       Acoustic or
       visual limiter
       or indicator.



                                         SWL                                    Excavators carrying out lifting operations MUST have the bucket removed
                                                                                prior to lifting. Not doing this can result in abnormal stress on the lifting
                                                                                accessories and a failure of these.















                                              Boom lowering control (e.g. hose   Before lifting:  Remove the bucket   Use a swivel shackle
       Always be aware that SWL is reduced    burst check valves to ISO 8643:97),   and attach master link to the   between the load and lifting
       when lifting side on to the tracks.    if maximum lift is over 1,000kg.  designated lifting point.          point.




                                                                     Page 30
   27   28   29   30   31   32   33   34   35   36   37