Page 49 - PowerPoint Presentation
P. 49
Let’s all
UTILITY SERVICES WITHIN DEMOLITION SITES get home safely,
every day
Review all Services survey issued to site If live head or unidentified Project manager to issue
relevant service management team. services cannot be protected demolition permit with
reports and sufficiently to allow soft strip or drawing showing the
drawings Full review of survey to be carried out demo then Project management location including
received from by project manager. team must liaise with external conformation of isolated
client utilities company's to isolate services and limit of
Once scope of services is realised outside of demo boundary. demolition / soft strip
relevant subcontractors are under this permit.
contacted to isolate all incoming
services at the heads. Carried out by:
Carried out by: Project manager This will include the tracing
Project manager. of 2 x cut ends
ISSUE REPORTS AND Isolation certificates are Project Manager to revise Works Progress
DRAWINGS TO APPROVED issued, and services directly Demolition RAMS to reflect ensuring ongoing
SERVICES SUB- site side of the head are any residual risks remaining assessment of
CONTRACTORS AND physically cut. from services on site. services
REQUEST A SERVICES termination in
SURVEY (TAG AND TRACE) Issued from subcontractor to relation to works
project manager. Carried out by:
NOTE: Must show the location Project manager
of all incomings heads and Carried out by specialist
services runs subcontractor
Carried out by: Specialist
subcontractor PM to brief site team on survey
including any live services
remaining.
No demolition to be carried out if the risk of damage to live services is present.
Page 47