Page 68 - Visual Guidance Handbook
P. 68

Let’s all
                              EDGE PROTECTION SYSTEMS AND CATCHMENT                                               get home safely,
                              FANS                                                                                every day








                                                                                                          On the live deck (e.g. deck under
                                                                                       800mm              construction) edge protection will be
                                                                                                          extended to 1.8m by means of the K-
                                                                                                          Guard additional make up panel.  This will
                                                                                       1m                 provide additional protection to activities
                                                                                                          at the perimeter such as column
                                                                                                          construction.




                                                                On striking of the deck the edge protection will be moved back to the concrete slab
                                                                and attached to previously cast in anchors.  This will be carried out whilst edge
                                                                protection is attached to the falsework removing the risk of works at height.  Once edge
                                                                protection is fixed to slab, falsework edge protection will be removed. Edge protection
                                                                fixed to slab will be reduced to 1m.



                                                     Floor to soffit edge protection systems can be installed when falsework is struck (these
                                                     typically brace from floor to soffit so cannot be installed whilst falsework is in place).  This
                                                     will be via client request as it will be for the benefit of follow on trades.





                                                                                                    Dependant on risk assessment catchment
                                                                                                    fan systems can be installed.  These are
                                                                                                    available in 2 x sizes 3m and 4.6m.
                                                                                                    3m systems must be no more than 2 x floors
                                                                                                    below working deck.
                                                                                                    4.6m system can be 3 x floors below working
                                                                                                    deck.  This is to allow for the predicted
                                                                                                    distance an item will project from the deck
                                                                                                    if dropped.  Fans will be jumped with the
                                                                                                    progressing floors.